Intra-rater reliability of leg blood flow during dynamic exercise using Doppler ultrasound
Sachin B Amin1, Hendrik Mugele1, Florian E Dobler1
1Department Sport Science, Division of Performance Physiology and Prevention, University Innsbruck, Innsbruck, Austria.
Abstract:
Developing an exercise model that resembles a traditional form of aerobic exercise and facilitates a complete simultaneous assessment of multiple parameters within the oxygen cascade is critically for understanding exercise intolerances in diseased populations. Measurement of muscle blood flow is a crucial component of such a model and previous studies have used invasive procedures to determine blood flow kinetics; however, this may not be appropriate in certain populations. Furthermore, current models utilizing Doppler ultrasound use isolated limb exercise and while these studies have provided useful data, the exercise model does not mimic the whole-body physiological response to continuous dynamic exercise. Therefore, we aimed to measure common femoral artery blood flow using Doppler ultrasound during continuous dynamic stepping exercise performed at three independent workloads to assess the within day and between-day reliability for such an exercise modality. We report a within-session coefficient of variation of 5.8% from three combined workloads and a between-day coefficient of variation of 12.7%. These values demonstrate acceptable measurement accuracy and support our intention of utilizing this noninvasive exercise model for an integrative assessment of the whole-body physiological response to exercise in a range of populations.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Blood pressure in the Leg
Preparation:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: