Related Experiment Video
Updated: Oct 17, 2025

04:32
Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
Published on: December 20, 2024
522
Patient-Reported Outcomes in Middle Ear and Active Transcutaneous Bone Conduction Hearing Implants
Stephen E M Jones1, Rujuta Roplekar-Bance2, Richard Green1
1Department of Otolaryngology, Ninewells Hospital and Medical School, Ninewells Avenue, Dundee, United Kingdom.
The Journal of International Advanced Otology
|October 7, 2021
Summary
Patients reported high satisfaction with Vibrant Soundbridge (VSB) and Bonebridge (BB) hearing implants. Caution is advised for patients near device limits to manage expectations and ensure satisfaction.
Area of Science:
- Audiology and Otolaryngology
- Biomedical Engineering
- Medical Device Evaluation
Background:
- Hearing implants offer solutions for hearing loss.
- Patient satisfaction is a key outcome measure for medical devices.
- Understanding factors influencing satisfaction with hearing implants is crucial.
Purpose of the Study:
- To assess patient-reported satisfaction with two hearing implant devices: Vibrant Soundbridge (VSB) and Bonebridge (BB).
- To identify factors predicting perceived outcomes (good or poor).
- To pinpoint specific aspects of the devices associated with dissatisfaction.
Main Methods:
- A post-treatment questionnaire survey was administered to 39 adult patients with VSB or BB implants.
- The survey included the Glasgow Benefit Inventory (GBI) and Hearing Device Satisfaction Scale (HDSS) with at least 3 months follow-up.
- Satisfaction scores were correlated with pre- and post-operative audiologic outcomes and between GBI and HDSS scores.
Main Results:
- 28 of 39 patients (72%) responded, with 13 BB and 15 VSB recipients at a mean of 13 months post-implantation.
- Overall satisfaction was high, with 25 of 28 responders largely satisfied across most HDSS domains.
- Three dissatisfied patients were near the manufacturer's recommended implantation limits; two were non-users, one did not achieve expected benefit.
Conclusions:
- High patient satisfaction levels were demonstrated for both Vibrant Soundbridge and Bonebridge implantable hearing devices.
- Implant teams should exercise caution and manage patient expectations when patients are near the recommended limits for these devices.