Related Experiment Video
Updated: Oct 17, 2025

Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Hypotension Prediction Index with non-invasive continuous arterial pressure waveforms (ClearSight): clinical
Luciano Frassanito1, Pietro Paolo Giuri2, Francesco Vassalli2
1Department of Scienze dell'Emergenza, Anestesiologiche e della Rianimazione, IRCCS Fondazione Policlinico A. Gemelli, Rome, Italy. lucfras75@hotmail.com.
Abstract:
Intraoperative hypotension (IOH) is common during major surgery and is associated with a poor postoperative outcome. Hypotension Prediction Index (HPI) is an algorithm derived from machine learning that uses the arterial waveform to predict IOH. The aim of this study was to assess the diagnostic ability of HPI working with non-invasive ClearSight system in predicting impending hypotension in patients undergoing major gynaecologic oncologic surgery (GOS). In this retrospective analysis hemodynamic data were downloaded from an Edwards Lifesciences HemoSphere platform and analysed. Receiver operating characteristic curves were constructed to evaluate the performance of HPI working on the ClearSight pressure waveform in predicting hypotensive events, defined as mean arterial pressure < 65 mmHg for > 1 min. Sensitivity, specificity, positive predictive value and negative predictive value were computed at a cutpoint (the value which minimizes the difference between sensitivity and specificity). Thirty-one patients undergoing GOS were included in the analysis, 28 of which had complete data set. The HPI predicted hypotensive events with a sensitivity of 0.85 [95% confidence interval (CI) 0.73-0.94] and specificity of 0.85 (95% CI 0.74-0.95) 15 min before the event [area under the curve (AUC) 0.95 (95% CI 0.89-0.99)]; with a sensitivity of 0.82 (95% CI 0.71-0.92) and specificity of 0.83 (95% CI 0.71-0.93) 10 min before the event [AUC 0.9 (95% CI 0.83-0.97)]; and with a sensitivity of 0.86 (95% CI 0.78-0.93) and specificity 0.86 (95% CI 0.77-0.94) 5 min before the event [AUC 0.93 (95% CI 0.89-0.97)]. HPI provides accurate and continuous prediction of impending IOH before its occurrence in patients undergoing GOS in general anesthesia.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Aneurysm IV: Nursing Management
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure

