Related Experiment Video
Updated: Oct 17, 2025

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023
The IAEA remote and automated quality control methodology for radiography and mammography
Patricia Mora1, Douglas Pfeiffer2, Gouzhi Zhang3
1San José, Costa Rica.
Abstract:
Radiography remains the most widely used imaging modality throughout the world. Additionally, while it has been demonstrated that a quality control (QC) program, especially in mammography, improves image quality, weekly technologist QC testing might be lacking even where there is clinical qualified medical physicist (CQMP) support. Therefore, the International Atomic Energy Agency (IAEA) developed simple QC phantoms that can easily be used on a regular basis (daily/weekly) for radiography and mammography. These are simple in design and use materials that are easily accessible in most parts of the world. A software application is also developed that automatically analyzes images and Digital Imaging and Communications in Medicine (DICOM) header information. It exports data to a comma-separated values (CSV) file that is read by a Microsoft Excel® spreadsheet for documentation and graphical analysis. The phantom and the software were tested in four institutions (in Costa Rica and the United States of America) both on computed radiography and direct digital mammography and radiography systems. Data were collected over a 3-year period. No corrective actions were taken on the data, but service was performed on two of the units. Results demonstrated noise that could be attributed to suboptimal placement of the phantom and incorrect data being put into the DICOM header. Preliminary evaluation of the IAEA methodology has demonstrated that it can provide meaningful QC data that are sensitive to changes in the imaging systems. Care must be taken at implementation to properly train personnel and ensure that the image data, including the DICOM header, are being correctly transmitted. The methodology gives the opportunity for a single CQMP to provide QC services even to remote sites where travel is prohibitive, and it is feasible and easy to implement.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Quality Assurance
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...