Chemical Analysis of Water-accommodated Fractions of Crude Oil Spills Using TIMS-FT-ICR MS
Published on: March 3, 2017
Online Coupling of Liquid Chromatography with Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at 21 T
Steven M Rowland1,2, Donald F Smith1, Gregory T Blakney1
1National High Magnetic Field Laboratory, Florida State University, Tallahassee, Florida 32310, United States.
Abstract:
High magnetic field Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry provides the highest mass resolving power and mass measurement accuracy for detailed characterization of complex chemical mixtures. Here, we report the coupling of online liquid chromatography of complex mixtures with a 21 tesla FT-ICR mass spectrometer. The high magnetic field enables large ion populations to be analyzed for each spectrum for a high dynamic range, with 3.2 million mass resolving power at m/z 400 (6.2 s transient duration) or 1.6 million (3.1 s transient duration) while maintaining high mass accuracy for molecular formula assignment (root-mean-square assignment error < 0.150 ppm). Thousands of unique elemental compositions are assigned per mass spectrum, which can be grouped by the heteroatom class, double bond equivalents (the number of rings and double bonds to carbon), and carbon number. Figures of merit are discussed, as well as characterization of an Arabian heavy vacuum gas oil in terms of the ring number, compound class, double bond equivalents, and ion type. Consideration of elemental composition and retention order provides additional structural information.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Instrumentation
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...