A method for improving the accuracy of calibration-free laser-induced breakdown spectroscopy by exploiting
Zhenlin Hu1, Feng Chen1, Deng Zhang1
1Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China.
Abstract:
The existence of the self-absorption effect results in a nonlinear relationship between spectral intensity and elemental concentration, which dramatically affect the quantitative accuracy of laser-induced breakdown spectroscopy (LIBS), especially calibration-free LIBS (CF-LIBS). In this work, the CF-LIBS with columnar density and standard reference line (CF-LIBS with CD-SRL) was proposed to improve the quantitative accuracy of CF-LIBS analysis by exploiting self-absorption. Our method allows using self-absorbed lines to perform the calibration-free approach directly and does not require self-absorption correction algorithms. To verify this method, the experiment was conducted both on aluminium-bronze and aluminium alloy samples. Compared with classical CF-LIBS, the average errors (AEs) of CF-LIBS with CD-SRL were decreased from 3.20%, 3.22%, 3.15% and 3.01%-0.95%, 1.00%, 1.16% and 1.78%, respectively for four aluminium-bronze alloy samples. The AEs were decreased from 0.66%, 0.70%, 0.89% and 1.30%-0.43%, 0.61%, 0.77% and 0.33%, respectively for four aluminium alloy samples. The experimental results demonstrated that CF-LIBS with CD-SRL provided higher quantitative accuracy and stronger adaptability than classical CF-LIBS, which is quite helpful for the practical application of CF-LIBS.
More Related Videos
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
03:49Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...