Related Experiment Video
Updated: Oct 17, 2025

Combination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Published on: September 12, 2014
Lyophilized amniotic membrane graft for primary pterygium surgery: preliminary results
Noelia Sabater-Cruz1,2, Eva Martinez-Conesa3,4, Anna Vilarrodona3,4
1Hospital Clinic de Barcelona, C/ Sabino de Arana S/N, 08028, Barcelona, Spain. noelia.sabater@gmail.com.
Abstract:
The aim of this study was to investigate the tolerability, safety and efficacy of new lyophilized amniotic membrane (LAM) presentation for ocular use. A prospective case-series cohort of four patients with primary nasal pterygium which undergone excision and LAM implantation was evaluated for complications and clinical outcomes. Surgical manipulation of LAM was also assessed. LAM was stiff and easy to manipulate as well as no tearing occurred during surgery or suturing. Ocular comfort was checked and similar among those patients with LAM glued or sutured. After 12 months, there were no issues about tolerability or adverse events. Lower cosmetic outcomes (recurrence) were stated in 3 patients. Our study showed that LAM could be an effective alternative to cryopreserved amniotic membrane for graft after pterygium excision surgery. Its main advantage, storage at room temperature, can make it of immediate availability. Further studies comparing clinical outcomes of pterygium surgery with cryopreserved amniotic membrane versus LAM would confirm the benefits of the last.