Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Class comparison enabled mass spectrum purification for comprehensive two-dimensional gas chromatography with
Grant S Ochoa1, Paige E Sudol1, Timothy J Trinklein1
1Department of Chemistry, University of Washington, Box 351700, Seattle, WA, 98195, USA.
Abstract:
Tile-based Fisher ratio (F-ratio) analysis is emerging as a versatile data analysis tool for supervised discovery-based experimentation using comprehensive two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC-TOFMS). None the less, analyte identification can often be marred by poor 2D resolution and low analyte abundance relative to overlapping compounds. Linear algebra-based chemometric methods, in particular multivariate curve resolution alternating least squares (MCR-ALS), parallel factor analysis (PARAFAC) and PARAFAC2, are often applied in an effort to address this situation. However, these chemometric methods can fail to produce an accurate spectrum when the analyte is at low 2D resolution and/or in low relative abundance. To address this challenge, we introduce class comparison enabled mass spectrum purification (CCE-MSP), a method that utilizes the underlying requirement for signal consistency of the background interference compounds between the two classes in the F-ratio analysis to purify the mass spectrum of the analyte hits. CCE-MSP is validated using a dataset obtained for a neat JP-8 jet fuel spiked with 14 sulfur containing compounds at two levels (15 ppm and 30 ppm), using the p-value and lack-of-fit (LOF) for each analyte hit as consistency metrics. A purified mass spectrum was produced for each spiked analyte hit and their mass spectrum match value (MV) was compared to the MV obtained by MCR-ALS, PARAFAC, and PARAFAC2. The resulting MV for CCE-MSP were found to be as good or better than these chemometric methods, eg., for 2-butyl-5-ethylthiophene with an analyte-to-interference relative signal abundance of 1:87 and a 2D resolution of 0.2, CCE-MSP produced a MV of 831, compared to 476 for MCR-ALS, 403 for PARAFAC, and 336 for PARAFAC2. CCE-MSP is also extended to obtain the purified spectrum for more than one analyte, eg., two analyte hits in overlapping hit locations. The spectra produced by CCE-MSP can also be utilized as estimates to facilitate quantitative signal decomposition using MCR-ALS.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometers
Mass Analyzers: Overview