Abstract:
This study evaluates the patient radiation dose from the two-phase protocols of two different computed tomography (CT) systems and compares this with that delivered by the other similar protocols previously published. Two hundred and fourteen patients with primary hyperparathyroidism were included in the study with a two-phase CT scan between 2008 and 2020 by using a Toshiba Aquilion Prime 80 and a GE Light Speed 16. The standard 'neck' or a modified 'parathyroid' protocol was used. The patient dose was evaluated in terms of volumetric computed tomography dose index (CTDIvol), dose length product (DLP) and effective dose (ED) per acquisition protocol and CT system. CTDIvol and DLP were recorded retrospectively, while the ED was calculated based on DLP and an appropriate conversion coefficient. Comparisons of patient dose between the two protocols and two CT systems and the corresponding published values were established. A significantly lower patient dose (40.2-43.2%) than the GE system (p < 0.0001) resulted from the Toshiba system. The 'parathyroid' protocol resulted in a 6.5-9.6% lower patient dose than the standard 'neck' protocol. Compared with the literature, the lowest ED value (3.6 mSv) was observed since this protocol consists of a lowered tube voltage of 100 kVp, a reduced scan length for the pre-contrast phase and implementation of an iterative reconstruction algorithm.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...