Related Experiment Video
Updated: Oct 17, 2025

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Contemporary Mechanical Circulatory Support With Continuous-Flow Biventricular Assist Devices: A Systematic Review
Lauren E Meece1, Julia Yu2, Eric I Jeng3
1From the Division of Cardiovascular Medicine, University of Florida, Gainesville, FL.
Abstract:
As the incidence of heart failure increases, so too has that of biventricular failure. While transplantation remains the gold standard therapy for end-stage heart failure, the limited organ supply has increased the need for durable mechanical circulatory support. We therefore sought to conduct a systematic review of continuous-flow ventricular assist devices in a biventricular configuration (CF-BiVAD). An electronic search of PubMed and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases was performed using the keyword "BIVAD." Studies were reviewed to identify discrete variables, including implant indication, INTERMACs profile, timing of implant, mean age and BMI, and the anticoagulation/antiplatelet regimens employed post implant. Outcomes of interest included mortality and the incidence of thrombus, bleeding, infection, stroke, and renal failure. A total of 25 studies met inclusion criteria. No single variable was consistently reported, with only 4 studies reporting all 5 adverse effects. INTERMACs profile at implant and anticoagulation/antiplatelet regimen were reported in less than 50% of studies. Of those reporting mortality, there was a wide range of follow-up, from less than 6 months to >10 years, and the survival rate was similarly widely variable. Additionally, more than 50% of studies failed to isolate CF-BiVAD from alternative means of biventricular support, such as temporary support platforms, TAH, and pulsatile VADs. Therefore, high-quality quantitative analysis is not possible. In summary, the CF-BiVAD literature has a very heterogenous reporting of data. Standard reporting criteria may allow for future analyses to determine which patient characteristics portend a favorable outcome with CF-BiVAD implantation.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Heart Failure VI: Adjunct Therapies
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Aortic Regurgitation III: Medical Management
Cardiomyopathy V: Interprofessional Care
Continuous Renal Replacement Therapy