Wide-field vitreoretinal surgery in eyes with Boston type 1 keratoprosthesis
Canan Asli Utine1,2, Mahmut Kaya3, Kıvanç Kasal3
1Department of Ophthalmology, Dokuz Eylul University, Mithatpasa cad No: 1606 Balcova, 35340, Izmir, Turkey. cananutine@gmail.com.
Purpose:
Vitreoretinal surgery in eyes with Boston type 1 keratoprosthesis (KPro) is challenging due to narrow optic of the KPro. This study analyzed the results of pars plana vitrectomy (PPV) using a wide-field imaging accessory, Resight®700 Fundus Viewing System (Carl Zeiss Meditec, Inc., Germany), for better intraoperative peripheral retinal imaging.
Methods:
In this retrospective case series, KPro patients who underwent simultaneous or sequential PPV at Dokuz Eylul University Hospital between June 2010 and January 2020 were evaluated in terms of anatomic and visual prognoses, as well as KPro- and PPV-associated complications.
Results:
Among 9 KPro eyes that necessitated vitreoretinal surgery, 3 (33.3%) underwent simultaneous KPro and PPV due to proliferative vitreoretinopaties; 6 (66.7%) underwent PPV for retinal detachment or suprachoroidal hemorrhage that appeared after KPro surgery. Retina could be attached in 7 eyes (77.8%), and vision improved in 3 eyes (33.3%). In 1 eye, injected silicone oil moved to subconjunctival area through glaucoma drainage device.
Conclusion: