The Behavior of Polyurethane Foam-Filled Glass-Fiber-Reinforced Polymer Crossarm Subjected to Lightning Transient

Muhammad Syahmi Abd Rahman1, Mohd Zainal Abidin Ab Kadir2, Muhamad Safwan Abd Rahman1

  • 1Institute of Power Engineering, Universiti Tenaga Nasional, Kajang 43000, Selangor, Malaysia.

Related Concept Videos

Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
252
Cable Subjected to Concentrated Loads01:28

Cable Subjected to Concentrated Loads

Flexible cables are commonly used in various applications for support and load transmission. Consider a cable fixed at two points and subjected to multiple vertically concentrated loads. Determine the shape of the cable and the tension in each portion of the cable, given the horizontal distances between the loads and supports.
1.1K
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
179
Capacitor With A Dielectric01:18

Capacitor With A Dielectric

Parallel plate capacitors consist of two conducting plates separated by a certain distance. However, it is mechanically difficult to hold the large plates parallel to each other without actual contact. Hence, a dielectric layer is commonly placed between the plates, which provides an easy solution for holding the plates together with a small gap and increases the capacitance of the capacitor.
Dielectrics are non-conducting materials with no free or loosely bound electrons. When a dielectric is...
4.3K
Cable Subjected to a Distributed Load01:24

Cable Subjected to a Distributed Load

The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
851
Electrostatic Boundary Conditions in Dielectrics01:27

Electrostatic Boundary Conditions in Dielectrics

When an electric field passes from one homogeneous medium to another, crossing the boundary between the two mediums imparts a discontinuity in the electric field. This results in electrostatic boundary conditions that depend on the type of mediums the field propagates through.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's...
1.4K