Lisa M Schiefer1,2, Gunnar Treff3, Franziska Treff1
1Department of Anesthesiology, Critical Care and Pain Medicine, Paracelsus Medical University, 5020 Salzburg, Austria.
Abstract:
Decreased oxygen saturation (SO2) at high altitude is associated with potentially life-threatening diseases, e.g., high-altitude pulmonary edema. Wearable devices that allow continuous monitoring of peripheral oxygen saturation (SpO2), such as the Garmin Fēnix® 5X Plus (GAR), might provide early detection to prevent hypoxia-induced diseases. We therefore aimed to validate GAR-derived SpO2 readings at 4559 m. SpO2 was measured with GAR and the medically certified Covidien Nellcor SpO2 monitor (COV) at six time points in 13 healthy lowlanders after a rapid ascent from 1130 m to 4559 m. Arterial blood gas (ABG) analysis served as the criterion measure and was conducted at four of the six time points with the Radiometer ABL 90 Flex. Validity was assessed by intraclass correlation coefficients (ICCs), mean absolute percentage error (MAPE), and Bland-Altman plots. Mean (±SD) SO2, including all time points at 4559 m, was 85.2 ± 6.2% with GAR, 81.0 ± 9.4% with COV, and 75.0 ± 9.5% with ABG. Validity of GAR was low, as indicated by the ICC (0.549), the MAPE (9.77%), the mean SO2 difference (7.0%), and the wide limits of agreement (-6.5; 20.5%) vs. ABG. Validity of COV was good, as indicated by the ICC (0.883), the MAPE (6.15%), and the mean SO2 difference (0.1%) vs. ABG. The GAR device demonstrated poor validity and cannot be recommended for monitoring SpO2 at high altitude.
More Related Videos
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Factors Affecting Respiration
Special considerations while measuring pulse