Firmware Update Using Multiple Gateways in LoRaWAN Networks

Christia Charilaou1, Spyros Lavdas2, Ala Khalifeh3

  • 1Department of Computer Science, University of Cyprus, Nicosia 1678, Cyprus.

Summary

Multiple gateways significantly improve firmware updates over the air (FUOTA) for IoT devices. Using several gateways eliminates trade-offs, enhancing efficiency and reducing power consumption during LoRaWAN FUOTA processes.

Related Concept Videos

Network Function of a Circuit01:25

Network Function of a Circuit

Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
428
Underflow Gates01:30

Underflow Gates

Underflow gates are vital for controlling water flow in irrigation canals. The three main types of underflow gates — vertical, radial, and drum gates — serve different purposes while ensuring effective flow management. Vertical gates move up and down, generating a free-flowing water jet; radial gates pivot to regulate the flow; and drum gates rotate for precise adjustments. The flow through these gates is influenced by downstream conditions, resulting in free or drowned outflow.Free and...
137
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
251
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
160
Multiple Voltage Sources01:25

Multiple Voltage Sources

Generally, a single battery is not enough to power some devices. In such cases, batteries can be combined in two ways: in series or in parallel.
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
1.3K
LC Circuits01:21

LC Circuits

An LC circuit consists of an inductor and a capacitor, either in series or parallel. Consider a charged capacitor connected with an inductor in series. Before the switch is closed, all the energy of the circuit is stored in the electric field of the capacitor. When the switch is closed, the capacitor begins to discharge, producing a current in the circuit. The current, in turn, creates a magnetic field in the inductor. Because of the induced emf in the inductor, the current cannot change...
2.7K