Related Experiment Video
Updated: Oct 17, 2025

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
Published on: December 15, 2023
Infratentorial lesions in multiple sclerosis patients: intra- and inter-rater variability in comparison to a fully
Julia Krüger1, Ann-Christin Ostwaldt2, Lothar Spies2
1jung diagnostics GmbH, Hamburg, Germany. julia.krueger@jung-diagnostics.de.
Objective:
Automated quantification of infratentorial multiple sclerosis lesions on magnetic resonance imaging is clinically relevant but challenging. To overcome some of these problems, we propose a fully automated lesion segmentation algorithm using 3D convolutional neural networks (CNNs).
Methods:
The CNN was trained on a FLAIR image alone or on FLAIR and T1-weighted images from 1809 patients acquired on 156 different scanners. An additional training using an extra class for infratentorial lesions was implemented. Three experienced raters manually annotated three datasets from 123 MS patients from different scanners.
Results:
The inter-rater sensitivity (SEN) was 80% for supratentorial lesions but only 62% for infratentorial lesions. There was no statistically significant difference between the inter-rater SEN and the SEN of the CNN with respect to the raters. For supratentorial lesions, the CNN featured an intra-rater intra-scanner SEN of 0.97 (R1 = 0.90, R2 = 0.84) and for infratentorial lesion a SEN of 0.93 (R1 = 0.61, R2 = 0.73).
Conclusion:
The performance of the CNN improved significantly for infratentorial lesions when specifically trained on infratentorial lesions using a T1 image as an additional input and matches the detection performance of experienced raters. Furthermore, for infratentorial lesions the CNN was more robust against repeated scans than experienced raters.
Key Points:
• A 3D convolutional neural network was trained on MRI data from 1809 patients (156 different scanners) for the quantification of supratentorial and infratentorial multiple sclerosis lesions. • Inter-rater variability was higher for infratentorial lesions than for supratentorial lesions. The performance of the 3D convolutional neural network (CNN) improved significantly for infratentorial lesions when specifically trained on infratentorial lesions using a T1 image as an additional input. • The detection performance of the CNN matches the detection performance of experienced raters.
More Related Videos
10:25Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
Published on: September 25, 2019
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014