Two-Dimensional Super-Resolution Visualization of Rat Brain Microvasculature Using Ultrasound Localization Microscopy
Published on: March 28, 2025
Faster super-resolution ultrasound imaging with a deep learning model for tissue decluttering and contrast agent
Katherine G Brown1, Scott Chase Waggener2, Arthur David Redfern3
1Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America.
Abstract:
Super-resolution ultrasound (SR-US) imaging allows visualization of microvascular structures as small as tens of micrometers in diameter. However, use in the clinical setting has been impeded in part by ultrasound (US) acquisition times exceeding a breath-hold and by the need for extensive offline computation. Deep learning techniques have been shown to be effective in modeling the two more computationally intensive steps of microbubble (MB) contrast agent detection and localization. Performance gains by deep networks over conventional methods are more than two orders of magnitude and in addition the networks can localize overlapping MBs. The ability to separate overlapping MBs allows use of higher contrast agent concentrations and reduces US image acquisition time. Herein we propose a fully convolutional neural network (CNN) architecture to perform the operations of MB detection as well as localization in a single model. Termed SRUSnet, the network is based on the MobileNetV3 architecture modified for 3-D input data, minimal convergence time, and high-resolution data output using a flexible regression head. Also, we propose to combine linear B-mode US imaging and nonlinear contrast pulse sequencing (CPS) which has been shown to increase MB detection and further reduce the US image acquisition time. The network was trained within silicodata and tested onin vitrodata from a tissue-mimicking flow phantom, and onin vivodata from the rat hind limb (N = 3). Images were collected with a programmable US system (Vantage 256, Verasonics Inc., Kirkland, WA) using an L11-4v linear array transducer. The network exceeded 99.9% detection accuracy onin silicodata. The average localization accuracy was smaller than the resolution of a pixel (i.e.λ/8). The average processing time on a Nvidia GeForce 2080Ti GPU was 64.5 ms for a 128 × 128-pixel image.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Super-resolution Fluorescence Microscopy
Imaging Studies II: Ultrasonography