Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Body composition analysis in patients with acute heart failure: the Scale Heart Failure trial
Fiorangelo De Ieso1,2, Markus Reinhold Mutke1,2, Noe Karl Brasier1
1CMIO Office, University Hospital Basel, Basel, Switzerland.
Aims:
In this study, we aimed to investigate whether body composition analysis (BCA) derived from bioelectrical impedance vector analysis (BIVA) could be used to monitor the hydration status of patients with acute heart failure (AHF) during intensified diuretic therapy.
Methods And Results:
This observational, single-centre study involved a novel, validated eight-electrode segmental body composition analyser to perform BCA derived from BIVA with an alternating current of 100 μA at frequencies of 5, 7.5, 50, and 75 kHz. The BCA-derived and BIVA-derived parameters were estimated and compared with daily body weight measurements in hospitalized patients with AHF. A total of 867 BCA and BIVA assessments were conducted in 142 patients (56.3% men; age 76.8 ± 10.7 years). Daily changes in total body water (TBW) and extracellular water (ECW) were significantly associated with changes in body weight in 62.2% and 89.1% of all measurements, respectively (range, ±1 kg). Repeated measures correlation coefficients between weight loss and TBW loss resulted with rho 0.43, P < 0.01, confidence interval (CI) [0.36, 0.50] and rho 0.71, P > 0.01, CI [0.67, 0.75] for ECW loss. Between the first and last assessments, the mean weight loss was -2.5 kg, compared with the -2.6 L mean TBW loss and -1.7 L mean ECW loss. BIVA revealed an increase in mean Resistance R and mean Reactance Xc across all frequencies, with the subsequent reduction in body fluid (including corresponding body weight) between the first and last assessments.
Conclusions:
Body composition analysis derived from BIVA with a focus on ECW is a promising approach to detect changes in hydration status in patients undergoing intensified diuretic therapy. Defining personalized BIVA reference values using bioelectrical impedance devices is a promising approach to monitor hydration status.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
Related Concept Videos
Heart Failure VII: Nursing Interventions
Heart Failure VI: Adjunct Therapies
Heart Failure III: Clinical Manifestations
Heart Failure II: Pathophysiology
Heart Failure IV: Classification and Diagnostic Evaluation
Pathophysiology of Heart Failure