Related Experiment Video
Updated: Oct 16, 2025

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
Stress Analysis in AAA does not Predict Rupture Location Correctly in Patients with Intraluminal Thrombus
Fanny Lorandon1, Simon Rinckenbach2, Nicla Settembre3
1Department of Vascular and Endovascular Surgery, University Hospital of Besançon, Besançon, Saint Etienne, France..
Background:
A biomechanical approach to the rupture risk of an abdominal aortic aneurysm could be a solution to ensure a personalized estimate of this risk. It is still difficult to know in what conditions, the assumptions made by biomechanics, are valid. The objective of this work was to determine the individual biomechanical rupture threshold and to assess the correlation between their rupture sites and the locations of their maximum stress comparing two computed tomography scan (CT) before and at time of rupture.
Methods:
We included 5 patients who had undergone two CT; one within the last 6 months period before rupture and a second CT scan just before the surgical procedure for the rupture. All DICOM data, both pre- and rupture, were processed following the same following steps: generation of a 3D geometry of the abdominal aortic aneurysm, meshing and computational stress analysis using the finite element method. We used two different modelling scenarios to study the distribution of the stresses, a "wall" model without intraluminal thrombus (ILT) and a "thrombus" model with ILT.
Results:
The average time between the pre-rupture and rupture CT scans was 44 days (22-97). The median of the maximum stresses applied to the wall between the pre-rupture and rupture states were 0.817 MPa (0.555-1.295) and 1.160 MPa (0.633-1.625) for the "wall" model; and 0.365 MPa (0.291-0.753) and 0.390 MPa (0.343-0.819) for the "thrombus" model. There was an agreement between the site of rupture and the location of maximum stress for only 1 patient, who was the only patient without ILT.
Conclusions:
We observed a large variability of stress values at rupture sites between patients. The rupture threshold strongly varied between individuals depending on the intraluminal thrombus. The site of rupture did not correlate with the maximum stress except for 1 patient.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm III: Interprofessional Care
Aneurysm I: Introduction
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies