Accuracy of Spontaneous Breathing Trial Using ET-CPAP in Predicting Successful Extubation of Neonates
Azeem Khan1, Vikram Kumar1, Ali Shabbir Hussain2
1Neonatology, Indus Hospital and Health Network, Karachi, PAK.
Objective:
Extubation failure is common in mechanically ventilated neonates. Finding objective criteria for predicting successful extubation may help to reduce the incidence of failure and the length of mechanical ventilation (MV). We conducted this study to determine the accuracy of the spontaneous breathing trial (SBT) and lung function measurements in predicting successful extubation in neonates.
Methodology:
This cross-sectional validation study was conducted at a tertiary care neonatal intensive care unit (NICU) over 12 months from December 2019 to December 2020. Neonates intubated for >24 hours and considered ready for extubation were enrolled in the study. Neonates who met defined eligibility criteria underwent a three minutes SBT using endotracheal continuous positive airway pressure (ET-CPAP) before extubation. The primary clinical team was blinded to the results, and all neonates were extubated after SBT. Extubation was considered successful if patients remained extubated for 48 hours.
Results:
Among the 107 infants, 77.5% (n=83) of infants passed the SBT. Of these, 78 were successfully extubated, giving the positive predictive value of 93.97%. The overall extubation success rate was 90% (n=96). The sensitivity and specificity of SBT were 81.2% and 54.5%, respectively. VE (ET-CPAP) and VE-ventilator at a cutoff of ≥238 ml and ≥143.7 ml have an area under the curve (AUC) of 0.77 and 0.75 respectively to predict successful extubation (p-value 0.003, 0.008 respectively).
Conclusion:
SBT predicts extubation success with pronounced accuracy. Therefore, we propose SBT as a valuable and crucial step that guides clinicians' decision-making regarding extubation preparedness or impending failure in neonates.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: