Related Experiment Video
Updated: Oct 16, 2025

Intramucosal Inoculation of Squamous Cell Carcinoma Cells in Mice for Tumor Immune Profiling and Treatment Response Assessment
Published on: April 22, 2019
Positron Emission Tomography-Computed Tomography Parameters Predict Efficacy of Immunotherapy in Head and Neck
Songtao Zhang1, Runfang Zhang1, Wenbo Gong1
1Department of Thyroid and Head Neck, Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China.
Background:
This study aims to assess the association between positron emission tomography-computed tomography (PET-CT) parameters and the response to immune checkpoint inhibitors in unresectable head and neck squamous cell carcinoma (HNSCC).
Methods:
A total of 105 patients receiving immunotherapy (pembrolizumab or sintilimab with/without cisplatin) were retrospectively enrolled in this study; pretreatment data regarding metabolic tumor volume (MTV) and maximum standardized uptake value (SUVmax) were collected. The primary interest of the study was objective response rate (ORR), and the secondary was progression-free survival (PFS).
Results:
The mean total MTV was 40.6 cm3 (range: 8.5-100.3), ORRs in tumors with total MTV of ≥40.6 and <40.6 cm3 were 43.1% and 23.1%, respectively; the difference was statistically significant (p = 0.018). Survival analysis indicated similar PFS rates in the two groups (p = 0.057). The mean total SUVmax was 12.5, ORRs in tumors with total SUVmax ≥12.5 and <12.5 were 40.0% and 26.0%, respectively; the difference was not significant (p = 0.092). Survival analysis reported patients with total SUVmax of ≥12.5 had significantly worse PFS (p = 0.001) than patients with total SUVmax of <12.5.
Conclusions:
In HNSCC, total MTV ≥40.6 cm3 translated into improved clinical response but not into better PFS; total SUVmax had no effect on clinical response, but total SUVmax ≥12.5 was associated with worse PFS.
More Related Videos
09:34Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET