Related Experiment Video
Updated: Oct 16, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Costs and Outcomes Comparison of Diabetes Technology Usage Among People With Type 1 or 2 Diabetes Using Rapid-Acting
Carlos R Vallarino1, Siew H Wong-Jacobson1, Brian D Benneyworth1
1Eli Lilly and Company, Indianapolis, IN, USA.
Background:
Does initiation of a continuous glucose monitor (CGM) or insulin pump lower health care utilization and/or costs?
Methods:
Distinct cohorts of people with type 1 diabetes (T1D) or type 2 diabetes (T2D) using a blood glucose monitor (BGM), CGM, pump, or CGM with pump were identified from a large claims database. Patients ≥40 years old with 12 months of continuous enrollment before and after the device start date qualified for the study. Outcomes included one-year medical utilization and costs (minus device) for events such as hospitalizations and office visits. Generalized linear models were fitted, controlling for numerous baseline covariates. The Holm method corrected for the multiplicity of hypotheses tested.
Results:
Of the 8235 total patients, the BGM control group was the largest, had the lowest percentage of patients with T1D, and was significantly different from the device groups in most baseline categories. Formally, only two comparisons were statistically significant: Compared with BGM, the pump cohort had greater adjusted first-year total medical and office visit costs. Other secondary outcomes such as days hospitalized, emergency department visits and labs, favored pump. Most endpoints were favorable for CGM. Results for CGM with pump generally were intermediate between CGM and pump alone.
Conclusions:
During a one-year follow-up, unadjusted medical costs of both CGM and pump appear lower than BGM, but multivariable modeling yielded adjusted savings only for CGM use. Economic benefits might be observable sooner for CGMs than for pumps. Generalized linear models fitted to health care utilization event rates produced favorable results for both CGM and pump.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes Mellitus: Type 2 and Gestational
Diabetes: Symptoms, Diagnosis, and Complications