Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
A Method for More Accurate Determination of Resonance Frequency of the Cardiovascular System, and Evaluation of a
Lorrie R Fisher1, Paul M Lehrer2
1, Irvine, CA, USA.
Abstract:
This study validated a more exact automated method of determining cardiovascular resonance frequency (RF) against the "stepped" protocol described by Lehrer et al. (Appl Psychophysiol Biofeedback 25(3):177-191, https://doi.org/10.1023/a:1009554825745 , 2000; in Foundations of heart rate variability biofeedback: A book of readings, The Association for Applied Psychophysiology and Biofeedback, pp 9-19, 2016). Thirteen participants completed a 15-min RF determination session by each method. The "stepped" protocol assesses HRV in five 3-min stationary windows from 4.5 to 6.5 breaths per minute (bpm), decreasing in 0.5 bpm steps. Multiple criteria, subjectively weighted by the clinician, determines RF. For this study, the proposed method used a sliding window with a fixed rate of change (67.04 ms per breath) at each of 78 breath cycles ranging from 4.25 to 6.75 bpm. Its algorithm analyzes IBI to locate the midpoint of the 1-min region of stable maximum peak-trough variability. RF is quantified from breath duration at that point. The software generates a visual display of superimposed HR and breathing data. Thus, the new method fully automates RF determination. Eleven of the 13 matched pairs fell within the 0.5 bpm resolution of the stepped method. Comparisons of LF power generated by the autoregressive (AR) spectral method showed a strong correlation in LF power production by the stepped and sliding methods (R = 0.751, p = 0.000). The "sliding" pacing protocol was favored by 69% of participants (p < 0.02). The new, fully-automated, method may facilitate both in-person and remote HRV biofeedback training. Software is available open-source.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...