Feasibility evaluation of PET scan-time reduction for diagnosing amyloid-β levels in Alzheimer's disease patients
Zhao Peng1, Ming Ni2, Hongming Shan3
1School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230026, China.
Purpose:
To shorten positron emission tomography (PET) scanning time in diagnosing amyloid-β levels thus increasing the workflow in centers involving Alzheimer's Disease (AD) patients.
Methods:
PET datasets were collected for 25 patients injected with 18F-AV45 radiopharmaceutical. To generate necessary training data, PET images from both normal-scanning-time (20-min) as well as so-called "shortened-scanning-time" (1-min, 2-min, 5-min, and 10-min) were reconstructed for each patient. Building on our earlier work on MCDNet (Monte Carlo Denoising Net) and a new Wasserstein-GAN algorithm, we developed a new denoising model called MCDNet-2 to predict normal-scanning-time PET images from a series of shortened-scanning-time PET images. The quality of the predicted PET images was quantitatively evaluated using objective metrics including normalized-root-mean-square-error (NRMSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR). Furthermore, two radiologists performed subjective evaluations including the qualitative evaluation and a five-point grading evaluation. The denoising performance of the proposed MCDNet-2 was finally compared with those of U-Net, MCDNet, and a traditional denoising method called Gaussian Filtering.
Results:
The proposed MCDNet-2 can yield good denoising performance in 5-min PET images. In the comparison of denoising methods, MCDNet-2 yielded the best performance in the subjective evaluation although it is comparable with MCDNet in objective comparison (NRMSE, PSNR, and SSIM). In the qualitative evaluation of amyloid-β positive or negative results, MCDNet-2 was found to achieve a classification accuracy of 100%.
Conclusions:
The proposed denoising method has been found to reduce the PET scan time from the normal level of 20 min to 5 min but still maintaining acceptable image quality in correctly diagnosing amyloid-β levels. These results suggest strongly that deep learning-based methods such as ours can be an attractive solution to the clinical needs to improve PET imaging workflow.