Related Experiment Video
Updated: Oct 16, 2025

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Detection and Characterization of Thrombosis in Humans Using Fibrin-Targeted Positron Emission Tomography and
David Izquierdo-Garcia1, Pauline Désogère2, Anne L Philip3
1Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA; Harvard-MIT Department of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
Objectives:
The authors present a novel technique to detect and characterize LAA thrombus in humans using combined positron emission tomography (PET)/cardiac magnetic resonance (CMR) of a fibrin-binding radiotracer, [64Cu]FBP8.
Background:
The detection of thrombus in the left atrial appendage (LAA) is vital in the prevention of stroke and is currently performed using transesophageal echocardiography (TEE).
Methods:
The metabolism and pharmacokinetics of [64Cu]FBP8 were studied in 8 healthy volunteers. Patients with atrial fibrillation and recent TEEs of the LAA (positive n = 12, negative n = 12) were injected with [64Cu]FBP8 and imaged with PET/CMR, including mapping the longitudinal magnetic relaxation time (T1) in the LAA.
Results:
[64Cu]FBP8 was stable to metabolism and was rapidly eliminated. The maximum standardized uptake value (SUVMax) in the LAA was significantly higher in the TEE-positive than TEE-negative subjects (median of 4.0 [interquartile range (IQR): 3.0-6.0] vs 2.3 [IQR: 2.1-2.5]; P < 0.001), with an area under the receiver-operating characteristic curve of 0.97. An SUVMax threshold of 2.6 provided a sensitivity of 100% and specificity of 84%. The minimum T1 (T1Min) in the LAA was 970 ms (IQR: 780-1,080 ms) vs 1,380 ms (IQR: 1,120-1,620 ms) (TEE positive vs TEE negative; P < 0.05), with some overlap between the groups. Logistic regression using SUVMax and T1Min allowed all TEE-positive and TEE-negative subjects to be classified with 100% accuracy.
Conclusions:
PET/CMR of [64Cu]FBP8 is able to detect acute as well as older platelet-poor thrombi with excellent accuracy. Furthermore, the integrated PET/CMR approach provides useful information on the biological properties of thrombus such as fibrin and methemoglobin content. (Imaging of LAA Thrombosis; NCT03830320).
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET