InterDosi Monte Carlo simulations of photon and electron specific absorbed fractions in a voxel-based crab phantom
Jaafar El Bakkali1,2, Emily Caffrey3, Abderrahim Doudouh4,5
1Nuclear Medicine Department, Military Hospital Mohammed V, Rabat, Morocco. bahmedj@gmail.com.
Abstract:
InterDosi is a new in-house Monte Carlo code that aims at facilitating the use of the Geant4 toolkit for internal dosimetry using voxel-based phantoms. In the present work the dosimetric capabilities of this code are assessed by calculating self-irradiation specific absorbed fractions (SI-SAFs) in a voxel-based crab phantom. Recent standard human organ compositions and densities taken from ICRP Publication 110 have been used for material specifications of the four organs of a crab, namely, the heart, hepatopancreas, gills, and gonads, whereas the material assigned to the crab shell has been modeled based on literature values. The SI-SAFs were calculated for mono-energetic photons of energies between 10 and 4000 keV, and for mono-energetic electrons of energies between 100 and 4000 keV. The statistical errors corresponding to the calculated SI-SAFs were all less than 0.01%. The results obtained demonstrate that the simulated masses and volumes of the crab organs are in good agreement with those presented in the literature. In addition, the dosimetric results show that the calculated SI-SAFs are generally consistent with those reported in the literature, with some moderate differences due to differences in material specification. It is concluded that the InterDosi code can be successfully employed in internal dose estimations in small organisms, and it is suggested that material specifications specifically relating to crab tissues should be developed to provide more precise SI-SAFs.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Absorption of Radiation
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...