Related Experiment Video
Updated: Oct 16, 2025

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Fully-automated SPE coupled to UHPLC-MS/MS method for multiresidue analysis of 26 trace antibiotics in environmental
Ming Zheng1, Suwen Tang2, Yangyang Bao3
1Key Laboratory of Organic Compound Pollution Control Engineering, School of Environmental and Chemical Engineering, Shanghai University, Shanghai, 200444, China. zmshu@shu.edu.cn.
Abstract:
Achieving simultaneous determination of antibiotic multiresidues in environmental waters by solid phase extraction (SPE) coupled with ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) with detection limits ≤ ng L-1 is still a huge challenge. Moreover, the offline SPE procedure was performed manually, costly, and time-consuming, while the online SPE required precision pretreatment instruments that require highly-skilled personnel. In this paper, a fully automated SPE coupled with UHPLC-MS/MS method was developed for analysis of antibiotics (sulfonamides, quinolones, and macrolides) in water matrices. Sample preparation optimization included SPE materials and configuration (HLB disks), sample volume (500-1000 mL), and pH (pH = 3) with a flow rate at 2~5 mL min-1, and an elution procedure with 2 × 6 mL methanol, and 2 × 6 mL acetone. Meanwhile, the parameters for UHPLC-MS/S detection of analytes were optimized, including LC retention time, and MS parameters. The instrumental limits of detection (LOD) and quantification (LOQ) of analytes ranged from 0.01-0.72 μg L-1 and 0.05-2.39 μg L-1, respectively, with satisfactory linear calibration (R2 > 0.995) and precision (< 9.9%). Recoveries in spike samples ranged between 77.5-104.9% in pure water, 59.4-97.8% in surface water (SW), and 58.2-108.6% in wastewater effluent (WWE) with relative standard deviations ≤ 12.8%. The matrix effects observed for most analytes were suppression (0-28.1%) except for five analytes having presented enhancement (0-14.6 %) in SW or WWE. This method can basically meet the needs of trace antibiotic residues detection in waters, with examples of concentrations of detected antibiotics being lower than LOQ (LLQ) -94.47 ng L-1 in WWEs and LLQ-15.47 ng L-1 in SW in the lower reaches of the Yangtze River Basin.
More Related Videos
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019