Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Volume and surface coil simultaneous reception (VSSR) method for intensity inhomogeneity correction in MRI
Background:
Addressing intensity inhomogeneity is critical in magnetic resonance imaging (MRI) because associated errors can adversely affect post-processing and quantitative analysis of images (i.e., segmentation, registration, etc.), as well as the accuracy of clinical diagnosis. Although several prior methods have been proposed to eliminate or correct intensity inhomogeneity, some significant disadvantages have remained, including alteration of tissue contrast, poor reliability and robustness of algorithms, and prolonged acquisition time.
Objective:
In this study, we propose an intensity inhomogeneity correction method based on volume and surface coils simultaneous reception (VSSR).
Methods:
The VSSR method comprises of two major steps: 1) simultaneous image acquisition from both volume and surface coils and 2) denoising of volume coil images and polynomial surface fitting of bias field. Extensive in vivo experiments were performed considering various anatomical structures, acquisition sequences, imaging resolutions, and orientations. In terms of correction performance, the proposed VSSR method was comparatively evaluated against several popular methods, including multiplicative intrinsic component optimization and improved nonparametric nonuniform intensity normalization bias correction methods.
Results:
Experimental results show that VSSR is more robust and reliable and does not require prolonged acquisition time with the volume coil.
Conclusion:
The VSSR may be considered suitable for general implementation.
Related Concept Videos
Magnetic Resonance Imaging
NMR Spectrometers: Resolution and Error Correction
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...