Related Experiment Video
Updated: Oct 16, 2025

High-Speed Human Temporal Bone Sectioning for the Assessment of COVID-19-Associated Middle Ear Pathology
Published on: May 18, 2022
Clinical and technical determinants of positive temporal artery biopsy: a retrospective cohort study
Fatima Alnaimat1, Ahmad T Mansour2,3, Hamza Alduraidi4
1Department of Internal Medicine, Division of Rheumatology/School of Medicine, University of Jordan, Amman, 11942, Jordan. falnaimat@yahoo.com.
Abstract:
Temporal artery biopsy (TAB) is one of the diagnostic tools to confirm the diagnosis of giant cell arteritis (GCA). We aim to evaluate the clinical and technical determinants of a positive biopsy. Demographics, clinical, technical, and laboratory data of all TAB's performed between 2007 and 2019 at a single academic medical center. 107 biopsies performed for 103 patients were included; 72.9% were female, and 27.1% were male. The mean age at the time of biopsy was 67.1 ± 9.3 years. One biopsy was excluded for lack of arterial tissue content. Of the remaining 106, 19.6% were positive. The length of the biopsy and the number of arterial cross-sections were not significantly associated with its result. A positive biopsy was seen more in patients with low albumin (p = 0.010) and hypothyroidism (p = 0.017) but less in those with prior glucocorticoids treatment (p = 0.028). Predictors of a positive biopsy included male gender [OR 4.029, 95% CI (1.330-12.209), p = 0.014]; elevated ESR [OR 3.998, 95% CI (1.908-6.787), p = 0.023]; polymyalgia rheumatica (PMR) symptoms [OR 5.121, 95% CI (2.094-9.872), p = 0.001]; and advancing in age (6.5% per every additional year), [OR 1.065, 95% CI (1.005-1.130), p = 0.033]. 53.7% of the patients were eventually diagnosed with GCA; 39.2% of them were based on positive biopsy. In conclusion, old age, male gender, elevated ESR, and PMR symptoms increase the odds of positive TAB. Technical factors, such as biopsy length and the number of cross-sections, did not influence eventual biopsy results, highlighting the pivotal role of the clinical presentation of the patients in selecting patients for TAB.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...