Related Experiment Video
Updated: Oct 16, 2025

Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
Responsiveness and Inter-Rater Reliability of the Pulse Volume Recording Upstroke Ratio (PVRr)
Sara Mateen1, Jennifer Skolnik1, Lawrence Oresanya2
1Resident, Temple University Hospital Podiatric Surgical Residency Program, Philadelphia, PA.
The pulse volume recording upstroke ratio (PVRr) is a reliable measure for assessing lower extremity revascularization outcomes. This study confirms its responsiveness and inter-rater reliability in clinical practice.
Area of Science:
- Vascular Surgery
- Medical Imaging
- Biomedical Engineering
Background:
- Assessing the effectiveness of lower extremity revascularization is crucial for patient outcomes.
- The pulse volume recording upstroke ratio (PVRr) is a potential non-invasive measure for evaluating vascular interventions.
- Standardized validation of PVRr's clinical utility is needed.
Purpose of the Study:
- To evaluate the responsiveness of the pulse volume recording upstroke ratio (PVRr) after lower extremity revascularization.
- To assess the inter-rater reliability of PVRr measurements among healthcare professionals.
Main Methods:
- Analysis of a database of 389 subjects undergoing lower extremity revascularization.
- Inclusion criteria: pedal radiographs, pre- and post-revascularization PVRs, and regular pulsatile digital waveforms.
- Responsiveness assessed by postoperative percent change in PVRr versus digital pressures; reliability assessed via intraclass correlation coefficient (ICC).
Main Results:
- A statistically significant negative correlation (Pearson -0.421; p=0.007) was found between digital pressures and PVRr, indicating responsiveness.
- As digital pressures increased post-revascularization, PVRr decreased.
- High inter-rater reliability for PVRr measurements was observed, with an ICC of 0.960.
Conclusions:
- The pulse volume recording upstroke ratio (PVRr) demonstrates significant responsiveness to changes in digital pressures post-revascularization.
- PVRr exhibits excellent inter-rater reliability, supporting its use as a consistent clinical measurement.
- These findings support the utility of PVRr in evaluating the success of lower extremity revascularization procedures.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:08Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Related Concept Videos
Regulation of Pulse
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Special considerations while measuring pulse
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...