Related Experiment Video
Updated: Oct 16, 2025

Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
Responsiveness and Inter-Rater Reliability of the Pulse Volume Recording Upstroke Ratio (PVRr)
Sara Mateen1, Jennifer Skolnik1, Lawrence Oresanya2
1Resident, Temple University Hospital Podiatric Surgical Residency Program, Philadelphia, PA.
Abstract:
The objective of this study was to evaluate a measure of the responsiveness and reliability of the pulse volume recording upstroke ratio (PVRr). A database of 389 subjects undergoing lower extremity revascularization was analyzed. Subjects were included in the analysis if they had undergone pedal radiographs, had PVRs performed pre- and postlower extremity revascularization, and had regular pulsatile digital waveforms with a pressure recording on both PVRs. The responsiveness of the PVRr was assessed by means of the postoperative percent change in comparison to the digital pressures. A statistically significant negative correlation was observed (Pearson -0.421; p = .007) indicating that as digital pressures increased, the PVRr decreased. Further, measurement of the reliability of the PVRr was performed on a selection of 10 recordings by 2 residents and 3 board-certified surgeons. The observed intraclass correlation coefficient of measurements was 0.960. Results of this investigation provide evidence in support of the responsiveness and inter-rater reliability in the calculation of the pulse volume recording upstroke ratio.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:08Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Related Concept Videos
Regulation of Pulse
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Special considerations while measuring pulse
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...