Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Instrumentation Amplifier01:25

Instrumentation Amplifier

769
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
769
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

351
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
351
Design Example01:23

Design Example

399
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
399
The Electromagnetic Spectrum02:37

The Electromagnetic Spectrum

60.5K
The electromagnetic spectrum consists of all the types of electromagnetic radiation arranged according to their frequency and wavelength. Each of the various colors of visible light has specific frequencies and wavelengths associated with them, and you can see that visible light makes up only a small portion of the electromagnetic spectrum. Because the technologies developed to work in various parts of the electromagnetic spectrum are different, for reasons of convenience and historical...
60.5K
NMR Spectrometers: Overview01:20

NMR Spectrometers: Overview

1.4K
NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
1.4K
IR Spectrum01:19

IR Spectrum

1.4K
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
1.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same journal

Traumatic dental injuries in the primary dentition: exploratory medico-legal framework for temporary damage assessment.

International journal of legal medicine·2026
Same journal

Postmortem case series of Δ<sup>8</sup>- and Δ<sup>9</sup>-tetrahydrocannabinol in blood and urine.

International journal of legal medicine·2026
Same journal

Smartphone-based photogrammetry and videogrammetry versus structured light scanning for the assessment of facial landmark distances and uncertainty.

International journal of legal medicine·2026
Same journal

Evaluation of bladder wash for postmortem toxicological analysis: Comparison with urine in 50 forensic cases.

International journal of legal medicine·2026
Same journal

Evaluation of the RTyper Y27 chip amplification system with Quick TargSeq 1.0 for Y-STR genotyping in forensic science.

International journal of legal medicine·2026
Same journal

Best practice for forensic anthropology reporting: a statement by the Board of the Forensic Anthropology Society of Europe (FASE).

International journal of legal medicine·2026

Related Experiment Video

Updated: Oct 16, 2025

Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
09:36

Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements

Published on: June 25, 2021

3.2K

First experiences with the Spectrum Compact CE System.

Nastasja Burgardt1, Melanie Weissenberger2

  • 1Institute of Forensic and Traffic Medicine, Department of Forensic Genetics, University Hospital Heidelberg, Voßstraße 2, Building 4420, 69115, Heidelberg, Germany. nastasja.burgardt@med.uni-heidelberg.de.

International Journal of Legal Medicine
|October 20, 2021
PubMed
Summary

The Promega Spectrum Compact CE System effectively analyzes short tandem repeat (STR) DNA fragments, demonstrating high precision and robustness for forensic genetics applications.

Keywords:
DNAForensic geneticsPromegaSTRSpectrum Compact CE System

More Related Videos

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

9.2K
High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

7.7K

Related Experiment Videos

Last Updated: Oct 16, 2025

Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
09:36

Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements

Published on: June 25, 2021

3.2K
Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

9.2K
High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
10:40

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy

Published on: June 28, 2016

7.7K

Area of Science:

  • Forensic Genetics
  • Molecular Biology
  • Analytical Chemistry

Background:

  • Capillary electrophoresis (CE) is crucial for DNA analysis in forensic science.
  • Evaluating new instrumentation is essential for advancing forensic genetic capabilities.

Purpose of the Study:

  • To assess the performance of the Promega Spectrum Compact CE System.
  • To determine its compatibility with commercial short tandem repeat (STR) kits.
  • To compare its reproducibility and robustness against the ABI PRISM® 310 Genetic Analyzer.

Main Methods:

  • Tested compatibility with 8 commercial STR kits from 4 manufacturers.
  • Evaluated reproducibility, including sizing precision, accuracy, and concordance.
  • Assessed robustness, focusing on sensitivity and mixture resolution.
  • Compared results with the ABI PRISM® 310 Genetic Analyzer.

Main Results:

  • The Spectrum Compact CE System successfully analyzed amplicons from all tested STR kits.
  • Demonstrated precision meeting manufacturer specifications.
  • Showed enhanced robustness compared to the ABI PRISM® 310 in certain aspects.
  • Achieved 1-basepair resolution and resolved mixture ratios down to 1:30.

Conclusions:

  • The Spectrum Compact CE System is a viable instrument for forensic DNA analysis.
  • It offers reliable performance for STR profiling and mixture analysis.
  • Provides advantages and limitations for forensic genetics laboratories.