[Confocal line-field OCT]
Sandra Schuh1, C Ruini2, E Sattler2
1Klinik für Dermatologie und Allergologie, Universitätsklinikum Augsburg, Sauerbruchstr. 6, 86179, Augsburg, Deutschland. sandra.schuh@uk-augsburg.de.
Abstract:
Optical coherence tomography (OCT) and confocal laser microscopy (CLSM) are established non-invasive methods in clinical dermatological routine diagnosis. Whereas CLSM is especially useful to distinguish between nevi and melanoma, OCT is suitable for the diagnosis and differentiation of non-melanoma skin cancer. Line-field confocal optical coherence tomography (LC-OCT) is a new innovative device, which has better cellular resolution than OCT and a higher penetration depth than CLSM. Similar to CLSM, LC-OCT also allows 3D images in real time to be taken. Therefore LC-OCT is very useful for the examination of skin lesions of all kinds, since it unites the features of CLSM and OCT.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Related Concept Videos
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Total Internal Reflection Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Super-resolution Fluorescence Microscopy
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...