Related Experiment Video
Updated: Oct 16, 2025

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Sensitivity to changes in rate of heartbeats as a measure of interoceptive ability
Dennis E O Larsson1,2, Giulia Esposito2,3, Hugo D Critchley2,4,5
1Department of Psychology, University of Sussex, Falmer, United Kingdom.
Abstract:
Individuals vary in their ability to perceive, as conscious sensations, signals like the beating of the heart. Tests of such interoceptive ability are, however, constrained in nature and reliability. Performance of the heartbeat tracking task, a widely used test of cardiac interoception, often corresponds well with individual differences in emotion and cognition, yet is susceptible to reporting bias and influenced by higher-order knowledge, e.g., of expected heart rate. The present study introduces a new way of assessing cardiac interoceptive ability, focusing on sensitivity to short-term, naturalistic changes in frequency of heartbeats. At rest, such heart rate variability typically reflects the dominant influence of respiration on vagus parasympathetic control of the sinoatrial pacemaker. We observed an overall tendency of healthy participants to report feeling fewer heartbeats during increases in heart rate, which we speculate reflects a reduction in heartbeat strength and salience during inspiratory periods when heart rate typically increases to maintain a stable cardiac output. Within-participant performance was more variable on this measure of cardiac interoceptive sensitivity relative to the "classic" heartbeat tracking task. Our findings indicate that cardiac interoceptive ability, rather than reflecting the veridical monitoring of subtle variations in physiology, appears to involve more interpolation wherein interoceptive decisions are informed by dynamic working estimates derived from the integration of afferent signaling and higher-order predictions.NEW & NOTEWORTHY This study presents a new method for evaluating cardiac interoceptive ability, measuring sensitivity to naturalistic changes in the number of heartbeats over time periods. Results show participants have an overall tendency toward sensing fewer heartbeats during higher heart rates. This likely reflects the influence of changing heartbeat strength on cardiac interoception at rest, which should be taken into account when evaluating cardiac interoceptive ability and its relationship to anxiety and psychosomatic conditions.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Regulation of Pulse
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...

