Increased blood pressure variability predicts poor outcomes from endovascular treatment for aneurysmal subarachnoid
Xin-Bo Ge1, Qun-Fu Yang1, Zhen-Bo Liu1
1Xingtai People's Hospital, Department of Neurosurgery, Xingtai, Hebei 054001, China.
Background:
Predictors of outcomes following endovascular treatment (ET) for aneurysmal subarachnoid hemorrhage (aSAH) are not well-defined. Identifying them would be beneficial in determining which patients might benefit from ET.
Objective:
To identify the predictive factors for poor outcomes following ET for aSAH.
Methods:
120 patients with ruptured cerebral aneurysms underwent endovascular embolization between January 2017 and December 2018. Blood pressure variability was examined using the standard deviation of the 24-hour systolic blood pressure (24hSSD) and 24-hour diastolic blood pressure (24hDSD). Predictors were identified through univariate and multivariate regression analysis. All patients were followed up for three months.
Results:
At follow-up, 86 patients (71.7%) had good outcomes and 34 (28.3%) had poor outcomes. Patients with poor outcomes had significantly higher 24hSSD than those with good outcomes (19.3 ± 5.5 vs 14.1 ± 4.8 mmHg; P < 0.001). The 24hDSD did not differ significantly between patients with good outcomes and those with poor outcomes (9.5 ± 2.3 vs 9.9 ± 3.5 mmHg; P = 0.464). The following were significant risk factors for poor outcomes after endovascular embolization: age ≥ 65 years (odds ratio [OR] = 23.0; 95% confidence interval [CI]: 3.0-175.9; P = 0.002); Hunt-Hess grade 3-4 (OR = 6.8; 95% CI: 1.1-33.7; P = 0.039); Fisher grade 3-4 (OR = 47.1; 95% CI: 3.8-586.5; P = 0.003); postoperative complications (OR = 6.1; 95% CI: 1.1-34.8; P = 0.042); and 24hSSD ≥ 15 mmHg (OR = 14.9; 95% CI: 4.0-55.2; P < 0.001).
Conclusion:
Elevated 24hSSD is a possibly treatable predictive factor for poor outcomes after ET for aSAH.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Aortic Regurgitation I: Introduction
Hypertension and Regulation of Blood Pressure
Factors affecting Blood pressure
Physiological Factors: