Review of extremity dosimetry in nuclear medicine
Robert Kollaard1, Alessandra Zorz2, Jérémie Dabin3
1Department of Radiation Protection, Consultancy and Services Division, Nuclear Research and Consultancy Group (NRG), Arnhem, The Netherlands.
Abstract:
The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of18F for diagnostic procedures and90Y for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using99mTc,18F and90Y), less information is available for more recent applications, such as the use of68Ga for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Absorption of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET