Related Experiment Video
Updated: Oct 16, 2025

An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
Impact of Airway Humidification Strategy in Mechanically Ventilated COVID-19 Patients
Carole-Anne Lavoie-Bérard1, Jean-Claude Lefebvre1, Pierre-Alexandre Bouchard2
1département d'anesthésiologie et de soins intensifs, division de soins intensifs, Université Laval, Québec City, Canada.
Background:
Humidification of inspiratory gases is mandatory in all mechanically ventilated patients in ICUs, either with heated humidifiers (HHs) or with heat and moisture exchangers (HMEs). In patients with COVID-19, the choice of the humidification device may have relevant impact on patients' management as demonstrated in recent studies. We reported data from 2 ICUs using either HME or HH.
Methods:
Data from patients with COVID-19 requiring invasive mechanical ventilation during the first wave in 2 ICUs in Québec City were reviewed. In one ICU, HMEs were used, whereas heated-wire HHs were used in the other ICU. We compared ventilator settings and arterial blood gases at day one after adjustment of ventilator settings. Episodes of endotracheal tube occlusions (ETOs) or subocclusions and a strategy to limit the risk of under-humidification were reported. On a bench test, we measured humidity with psychrometry with HH at different ambient temperature and evaluated the relation with heater plate temperature.
Results:
We reported data from 20 subjects positive for SARS-Cov-2, including 6 in the ICU using HME and 14 in the ICU using HH. In the HME group, PaCO was higher (48 vs 42 mm Hg) despite higher minute ventilation (171 vs 145 mL/kg/min predicted body weight [PBW]). We also reported 3 ETOs occurring in the ICU using HH. The hygrometric bench study reported a strong correlation between heater plate temperatures of the HH and humidity delivered. After implementation of measures to avoid under-humidification, including heater plate temperature monitoring, no more ETOs occurred.
Conclusions:
The choice of the humidification device used in subjects with COVID-19 had a relevant impact on ventilation efficiency (increased CO2 removal with lower dead space) and on complications related to low humidity, including ETOs that may be present with heated-wire HHs when used with high ambient temperatures.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Cardiopulmonary Resuscitation II: ACLS Airway Management
COPD: Management Using Bronchodilators and Corticosteroids
Mechanical Ventilation I: Indication and Settings