Related Experiment Video
Updated: Oct 16, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
[Prediction of the Incomplete Region of Fat Suppression Using the Banding Artifact of the Balanced Steady-state Free
Yuichi Takaki1, Masahiro Hashida2, Masanori Komi3
1Division of Radiology, Department of Medical Technology, Kumamoto University Hospital.
Abstract:
When the fat-suppression technique was used in the MRI examinations of neck and extremities, incomplete regions of fat suppression were depicted frequently. These incomplete regions were caused by the non-uniform static magnetic field (B0). On the other hand, a non-uniform B0 caused banding artifacts using a balanced steady-state free precession (bSSFP) sequence. We investigated the prediction of incomplete regions of fat suppression using the banding artifacts of the bSSFP sequence. The fat-suppression techniques used in this study were the chemical shift selective and spectral adiabatic inversion recovery methods for turbo spin echo imaging. Using an oil bottle attached to a staple, the scan parameters of the bSSFP sequence were adjusted to overlap with the banding artifacts in the incomplete regions of fat suppression. The neck, ankle joint and femur of healthy volunteers were scanned using the obtained scan parameters, and a visual assessment was performed. As a result, the incomplete region of fat suppression matched the region of the banding artifact. We were able to predict the incomplete region of fat suppression using the banding artifacts of the bSSFP sequence. If the optimized bSSFP sequence is used as the localizer, we can assess the situation of incomplete fat suppression before the main scanning and reduce rescanning due to incomplete fat suppression.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
IR Frequency Region: Fingerprint Region
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)