Related Experiment Video
Updated: Oct 16, 2025

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Transcatheter Aortic Valve Replacement with Minimal Contrast Dye in Patients with Renal Insufficiency
Jah Yeon Choi1, Geu-Ru Hong2, Sung-Jin Hong2
1Cardiovascular Center, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea.
Purpose:
Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR.
Materials And Methods:
We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m²) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated.
Results:
The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080-0.541, p=0.001).
Conclusion:
Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.
More Related Videos
08:12Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Continuous Renal Replacement Therapy