Related Experiment Video
Updated: Oct 16, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
How much should we be concerned about cumulative effective doses in medical imaging?
Colin J Martin1, Michael Barnard2
1Department of Clinical Physics and Bioengineering, University of Glasgow, Gartnaval Royal Hospital, Glasgow, United Kingdom.
Abstract:
The International Atomic Energy Agency issued a statement calling for action to strengthen the radiation protection of patients undergoing recurrent imaging. This followed reports of patients receiving cumulative effective doses over 100 mSv from multiple computed tomography examinations. In order to evaluate excess risks of cancer incidence among UK patients, data from an exposure management system covering three hospitals within one trust have been studied over 5½ years. Cumulative effective doses for 105 757 patients, from whom 719 (0.68%) received effective dose over 100 mSv, have been analysed using age and sex specific risk factors for stochastic effects. Two cancers might be expected to be initiated in the patients receiving over 100 mSv, while five might be expected to develop cancer among patients receiving 50-100 mSv. However, the calculations ignore health conditions for which the patients are being treated that may shorten their lives, and rely on the linear-no-threshold dose-effect model which is a subject of debate, so they are likely to overestimate cancer incidence. If health of the patients receiving >100 mSv is taken into account, the risk of mortality from cancer initiated by medical exposure might be the order of 1 in 2000. Recommendations on further strengthening of optimisation should be applied to imaging procedures for all patients with special focus on those performed on children and adolescents.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

