Quantum chemical insight into the effects of the local electron environment on T2*-based MRI
M S Petronek1,2, J J St-Aubin3, C Y Lee4
1Department of Radiation Oncology, University of Iowa, Iowa City, IA, USA. michael-petronek@uiowa.edu.
Abstract:
T2* relaxation is an intrinsic magnetic resonance imaging (MRI) parameter that is sensitive to local magnetic field inhomogeneities created by the deposition of endogenous paramagnetic material (e.g. iron). Recent studies suggest that T2* mapping is sensitive to iron oxidation state. In this study, we evaluate the spin state-dependence of T2* relaxation using T2* mapping. We experimentally tested this physical principle using a series of phantom experiments showing that T2* relaxation times are directly proportional to the spin magnetic moment of different transition metals along with their associated magnetic susceptibility. We previously showed that T2* relaxation time can detect the oxidation of Fe2+. In this paper, we demonstrate that T2* relaxation times are significantly longer for the diamagnetic, d10 metal Ga3+, compared to the paramagnetic, d5 metal Fe3+. We also show in a cell culture model that cells supplemented with Ga3+ (S = 0) have a significantly longer relaxation time compared to cells supplemented with Fe3+ (S = 5/2). These data support the hypothesis that dipole-dipole interactions between protons and electrons are driven by the strength of the electron spin magnetic moment in the surrounding environment giving rise to T2* relaxation.
More Related Videos
09:30Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
Related Concept Videos
Magnetic Resonance Imaging
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
Inductive Effects on Chemical Shift: Overview
π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...