Related Experiment Video
Updated: Oct 16, 2025

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Multicenter, Prospective, Randomized Study of Dexamethasone Intravitreal Implant in Patients with Center-Involved
Wenbin Wei1, Youxin Chen2, Bojie Hu3
1Beijing Tongren Hospital, Capital Medical University, Beijing, People's Republic of China.
Purpose:
To evaluate the safety and efficacy of dexamethasone intravitreal implant 0.7 mg (DEX) compared with laser photocoagulation in patients with diabetic macular edema (DME).
Patients And Methods:
This Phase 3, multicenter, randomized, efficacy evaluator-masked, parallel-group, 12-month clinical study enrolled adults in China and the Philippines with reduced visual acuity secondary to fovea-involved DME in the study eye. Participants were randomized 1:1 to study eye treatment with laser photocoagulation every 3 months as needed (n = 139) or DEX every 5 months (n = 145). The main efficacy measures were best-corrected visual acuity (BCVA), central retinal thickness (CRT), and leakage area. The primary endpoint was the average change in BCVA from baseline over 12 months (area-under-the-curve method). Preplanned subgroup analyses evaluated outcomes in Chinese patients.
Results:
Mean average change in BCVA from baseline during the study (letters) was 4.3 with DEX (n = 145) versus 1.4 with laser (n = 127) overall (P = 0.001) and 4.6 with DEX (n = 129) versus 0.6 with laser (n = 113) in Chinese patients (P < 0.001). At Month 12, mean change in CRT from baseline was -209.5 μm with DEX versus -120.3 μm with laser (P < 0.001) and mean change in total leakage area from baseline was -8.367 mm2 with DEX versus -0.637 mm2 with laser (P < 0.001). The most common treatment-emergent adverse events in the DEX group were increased intraocular pressure and cataract.
Conclusion:
DEX administered every 5 months provided significantly greater improvement in BCVA, CRT, and total leakage area compared with laser treatment. DEX demonstrated an acceptable safety profile, consistent with an intraocular corticosteroid, and similar to that reported in completed global registration studies.
More Related Videos
06:19Author Spotlight: A Novel Protocol for Intracameral Injections to Enhance Precision in Rodent Ophthalmology
Published on: May 31, 2024
10:24Regenerative Therapy by Suprachoroidal Cell Autograft in Dry Age-related Macular Degeneration: Preliminary In Vivo Report
Published on: February 12, 2018
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment