Related Experiment Video
Updated: Oct 16, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
The importance of calibration method in determining the association between central blood pressure with left
Satish Ramkumar1,2,3, Hong Yang4, Mark Nolan4
1Baker Heart and Diabetes Institute, 75 Commercial Road, Melbourne, VIC, 3004, Australia. satishramkumar2@gmail.com.
Abstract:
Afterload is an important determinant of left ventricular (LV) and atrial (LA) function, including myocardial strain. Central blood pressure (CBP) is the major component of cardiac afterload and independently associated with cardiovascular risk. However, the optimal means of calibrating CBP is unclear-standard CBP assessment uses systolic (SBP) and diastolic blood pressure (DBP) from brachial waveforms, but calibration with mean pressure (MAP) and DBP purports to be more accurate. Therefore, we sought to determine which CBP is best associated with LA and LV strain. CBP was measured using both standard and MAP based calibration methods in 546 participants (age 70.7 ± 4.7 years, 45% male) with risk factors for heart failure. Echocardiography was performed in all patients and strain analysis conducted to assess LA/LV function. The associations of CBP with LA and LV strain were assessed using linear regression. MAP-derived CSBP (150 ± 20 mmHg) was higher than standard CSBP (128 ± 15 mmHg) and brachial SBP (140 ± 17 mmHg, p < 0.001), whereas DBPs were similar (84 ± 10, 83 ± 10, and 82 ± 10 mmHg). MAP-derived CSBP was not independently associated with LV strain (p > 0.05), however was independently associated with LA reservoir strain (p < 0.05). Brachial and central DBP were more strongly associated with LA reservoir/conduit and LV strain than brachial and central SBP. LA pump strain was not independently associated with any SBP or DBP parameter (p > 0.05). MAP-derived CBP was more accurate in identifying patients with abnormal LA and LV strain than brachial SBP and standard CBP calibration. In conclusion, CBP calibrated using MAP and DBP may be more accurate in identifying patients with abnormal LA and LV function than standard brachial calibration methods.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

