Abstract:
Noise pollution from the environment may wreak havoc on a person's wellbeing. Numerous sound-absorbing materials are employed to address these issues, one of which is textile-woven fabrics. In this study, 12 woven textiles with four different weave structures (plain, rib, sateen, and twill) and those formed from three distinct polyester yarns were evaluated for their sound absorption properties using an impedance tube. The study was conducted within the range of 80-5000 (Hz) frequency. Part of the investigation was measuring different layers of woven fabrics under three different measuring conditions. Firstly, only woven fabrics were evaluated. Following that, woven and nonwoven textiles were measured. The third variant, in addition to the woven fabrics, included an air gap. In addition, this study includes tests and analyses of the effect of roughness and porosity of the fabric structure on the effectiveness of noise reduction by woven fabrics. The absorption capacity of plain fabric is higher at lower frequencies than other woven fabrics. Other weave structures noise reduction efficiency is higher as the frequency range increases. The absorption efficiency of plain fabric decreases with fabric layering. Utilizing woven fabric combined with nonwoven fabric reduces noise more effectively than the air gap variant. Low surface roughness and a highly porous surface of the fabric indicate a high noise reduction coefficient (NRC).
More Related Videos
Related Concept Videos
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
Viscosity
The SI unit of viscosity is...
Sound Waves: Interference
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...