Bronchodilator Delivery via High-Flow Nasal Cannula: A Randomized Controlled Trial to Compare the Effects of Gas
Jie Li1, Yibing Chen2, Stephan Ehrmann3,4
1Rush University Medical Center, Department of Cardiopulmonary Sciences, Division of Respiratory Care, Chicago, IL 60612, USA.
Abstract:
(1) Background: Aerosol delivery via high-flow nasal cannula (HFNC) has attracted increasing clinical interest. In vitro studies report that the ratio of HFNC gas flow to patient inspiratory flow (GF:IF) is a key factor in the efficiency of trans-nasal aerosol delivery. (2) Methods: In a randomized controlled trial, patients with a history of COPD or asthma and documented positive responses to inhaled bronchodilators in an outpatient pulmonary function laboratory were recruited. Subjects were randomized to receive inhalation at gas flow ratio settings of: GF:IF = 0.5, GF:IF = 1.0, or GF = 50 L/min. Subjects were assigned to inhale saline (control) followed by salbutamol via HFNC with cumulative doses of 0.5 mg, 1.5 mg, 3.5 mg, and 7.5 mg. Spirometry was performed at baseline and 10-12 min after each inhalation. (3) Results: 75 subjects (49 asthma and 26 COPD) demonstrating bronchodilator response were enrolled. Per the robust ATS/ERS criteria no difference was observed between flows, however using the criteria of post-bronchodilator forced expiratory volume in the first second (FEV1) reaching the screening post-bronchodilator FEV1 with salbutamol, a higher percentage of subjects receiving GF:IF = 0.5 met the criteria at a cumulative dose of 1.5 mg than those receiving GF:IF = 1.0, and GF = 50 L/min (64% vs. 29% vs. 27%, respectively, p = 0.011). Similarly at 3.5 mg (88% vs. 54% vs. 46%, respectively, p = 0.005). The effective dose at GF:IF = 0.5 was 1.5 mg while for GF = 50 L/min it was 3.5 mg. (4) Conclusions: During salbutamol delivery via HFNC, cumulative doses of 1.5 mg to 3.5 mg resulted in effective bronchodilation. Applying the robust ATS/ERS criteria no difference was observed between the flows, however using the more sensitive criteria of subjects reaching post screening FEV1 to salbutamol via HFNC, a higher number of subjects responded to the doses of 0.5 mg and 1.5 mg when HFNC gas flow was set at 50% of patient peak inspiratory flow.
More Related Videos
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
COPD: Management Using Bronchodilators and Corticosteroids
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...