Impact of Design and Deployment Technique on the Hydrodynamic Resistance of Flow Diverters : An in Vitro Experimental
Dániel Gyürki1, Benjamin Csippa2, György Paál2
1Department of Hydrodynamic Systems, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Műegyetem rkp. 3., D building, 3rd floor, 1111, Budapest, Hungary. dgyurki@hds.bme.hu.
Purpose:
Despite the high efficacy of flow diverters (FD) in treating sidewall intracranial aneurysms, failures are reported. One of the physical factors determining efficacy is the flow reducing capacity of the FD that is currently unknown to the operator. Our aim was to measure the flow reducing capacity expressed as the hydrodynamic resistance (HR), the metallic surface area (MSA) and pore density (PD) of two different FD designs and quantitatively investigate the impact of sizing and the deployment technique on these parameters.
Methods:
Altogether 38 Pipeline (Medtronic) and P64 (Phenox) FD‑s were implanted in holder tubes by a neurointerventionist in nominally sized, oversized and longitudinally compressed or elongated manners. The tubes were placed in a flow model with the flow directed across the FD through a side hole on the tube. HR was expressed by the measured pressure drop as the function of the flow rate. Deployed length, MSA and PD were also measured and correlated with the HR.
Results:
Both PD and MSA changed with varying deployment length, which correlates well with the change in HR. Oversizing the device by 1 mm in diameter has reduced the HR on average to one fifth of the original value for both manufacturers.
Conclusion:
This study demonstrates experimentally that different FD designs have different flow diverting capacities (HR). Parameters are greatly influenced by radial sizing and longitudinal compression or elongation during implantation. Our results might be useful in procedure planning, predicting clinical outcome, and in patient-specific numerical flow simulations.
More Related Videos
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Related Concept Videos
Design Example: Creating a Hydraulic Model of a Dam Spillway
Typical Model Studies
General External Flow Characteristics
Rapidly Varying Flow
Design Example: Forces in Sluice Gate
Key variables in...
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...