Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

7.7K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
7.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Cut-off values of serum homocysteine and high-sensitivity CRP for predicting early neurological improvement after intravenous thrombolysis.

BMC neurology·2026
Same author

Health Literacy and Cardiovascular Risk Factors: A Nationally Representative Study of Korean Adults.

American journal of preventive medicine·2026
Same author

Sex-Based Differences in Disease Burden and Phenotype in CADASIL: A Multicenter Study of 368 Korean Patients.

Neurology. Genetics·2026
Same author

Lactose-Free Fermented Milk Production Using <i>Lactococcus lactis</i> NK24 and NK34 with Immune-Enhancing Effects on RAW 264.7 Cells.

Journal of microbiology and biotechnology·2026
Same author

Decoding environmental regimes and spring phytoplankton bloom occurrence in the central Yellow Sea.

Scientific reports·2026
Same author

Perfusion Imaging-Based Triage for Acute Ischemic Stroke: Trends in Use and Impact on Clinical Outcomes.

Stroke (Hoboken, N.J.)·2026
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
See all related articles

Related Experiment Video

Updated: Oct 15, 2025

A Multimodal Imaging Framework to Advance Phenotyping of Living Label-free Breast Cancer Cells
10:37

A Multimodal Imaging Framework to Advance Phenotyping of Living Label-free Breast Cancer Cells

Published on: August 22, 2025

561

Open Platform Cameras Based Bio-Imaging Evaluation System.

Ji-Yeon Baek1, Jong-Dae Kim2,3, Yu-Seop Kim2,3

  • 1Help-Me Law Firm, Seoul 06158, Korea.

Sensors (Basel, Switzerland)
|October 26, 2021
PubMed
Summary
This summary is machine-generated.

This study compares smartphone and high-performance cameras for bio-imaging. Smartphone cameras show comparable linearity to expensive options, making them viable for bio-imaging applications.

Keywords:
bio-imaginggel electrophoresisgel-document systemopen platform-based camera

More Related Videos

Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
09:56

Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales

Published on: August 21, 2019

7.0K
Multimodal Optical Imaging Platform for Studying Cellular Metabolism
04:47

Multimodal Optical Imaging Platform for Studying Cellular Metabolism

Published on: June 6, 2025

726

Related Experiment Videos

Last Updated: Oct 15, 2025

A Multimodal Imaging Framework to Advance Phenotyping of Living Label-free Breast Cancer Cells
10:37

A Multimodal Imaging Framework to Advance Phenotyping of Living Label-free Breast Cancer Cells

Published on: August 22, 2025

561
Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
09:56

Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales

Published on: August 21, 2019

7.0K
Multimodal Optical Imaging Platform for Studying Cellular Metabolism
04:47

Multimodal Optical Imaging Platform for Studying Cellular Metabolism

Published on: June 6, 2025

726

Area of Science:

  • Biomedical Engineering
  • Imaging Technology
  • Mobile Device Applications

Background:

  • The proliferation of mobile devices has led to the mass production of compact, high-definition cameras.
  • These cameras are increasingly considered for bio-imaging applications, traditionally dominated by bulky, expensive equipment.

Purpose of the Study:

  • To establish an emulation system for evaluating bio-imaging performance.
  • To compare the linearity of brightness gradient changes across various cameras, including smartphones and high-performance models.
  • To assess the suitability of smartphone cameras for bio-imaging tasks.

Main Methods:

  • Development of a specialized emulation system for camera performance verification.
  • Analysis of the linearity of brightness gradient changes in four different camera types.
  • Selection of three cameras based on linearity performance.
  • Comparison of gel image analysis results from selected cameras.

Main Results:

  • Demonstrated comparable linearity in brightness gradient changes between select smartphone cameras and high-performance cameras.
  • Identified specific smartphone models suitable for bio-imaging based on linearity metrics.
  • Showcased the potential for smartphone cameras to yield comparable gel image analysis results.

Conclusions:

  • Smartphone cameras offer a cost-effective and accessible alternative for certain bio-imaging applications.
  • The established emulation system provides a reliable method for assessing camera bio-imaging performance.