Abstract:
Oxygen reserve index, available as part of Masimo Rainbow SET pulse oximetry, is a noninvasive and continuous variable intended to provide insight into a patient's oxygen status in the moderate hyperoxic range (PaO2 > 100 and ≤ 200 mm Hg), defined as a patient's oxygen "reserve". When used in conjunction with pulse oximetry, ORi extends the knowledge on a patient's oxygen status providing clinically important information helping to prevent hyperoxemia and hypoxemia. There are limited data on patients undergoing craniosynostosis surgery. Our primary goal was to evaluate the effects of different concentrations of inspiratory oxygen (FiO2) on patient oxygenation status by monitoring ORi. Thirty patients scheduled for craniosynostosis were included in this observational cohort study. Patients were randomized into two equal groups: Group 1 received a fraction of inspired oxygen of 0.8 and group 2 received a FiO2 of 0.6 during induction of anaesthesia. In addition to standard haemodynamic variables with ORi were recorded at baseline 1 min, 5 min, 60 min, and 120 min after intubation. Postoperative complications, length of stay in the intensive care unit and hospital were recorded. In total, 14 patients were evaluated in each group. Gender, age, BMI, ASA scores were similar between groups (p > 0.05). In Group 1, ORi values were significantly higher when compared to group 2 at baseline (0.86 ± 0.21 vs 0.45 ± 0.32, p = 0.001), one minute (0.61 ± 0.24 vs 0.27 ± 0.21, p = 0.001), and 5 min (0.34 ± 0.31 vs 0.10 ± 0.13, p = 0.033). High inspired oxygen concentration during induction of anesthesia in pediatric patients is associated with higher levels of ORi. Therefore, ORi may provide the means to safely reduce the inspired oxygen fraction during inhalational induction in paediatric patients.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen Transport in the Blood
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...