Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

10.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
10.0K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

4.5K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
4.5K
X-ray Imaging01:24

X-ray Imaging

8.6K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
8.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Factors Affecting Contrast Enhancement on CT Images.

Radiographics : a review publication of the Radiological Society of North America, Inc·2026
Same author

Effect of Patient Positioning on CT Number Accuracy: A Phantom Study Comparing Energy Integrating and Deep Silicon Photon Counting Detector CT.

Journal of computer assisted tomography·2025
Same author

Comparing fully automated AI body composition biomarkers at differing virtual monoenergetic levels using dual-energy CT.

Abdominal radiology (New York)·2024
Same author

Misinterpretations about CT numbers, material decomposition, and elemental quantification.

European radiology·2024
Same author

Consumable Material Waste and Workflow Efficiency Comparison Between Multi-use Syringeless and Single-use Syringe-Based Injectors in Computed Tomography.

Academic radiology·2023
Same author

CT Number Accuracy and Association With Object Size: A Phantom Study Comparing Energy-Integrating Detector CT and Deep Silicon Photon-Counting Detector CT.

AJR. American journal of roentgenology·2023

Related Experiment Video

Updated: Oct 15, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.6K

Sub pixel resolution using spectral-spatial encoding in x-ray imaging.

Timothy P Szczykutowicz1,2,3, Sean D Rose4, Alexander Kitt5

  • 1Department of Radiology, University of Wisconsin-Madison, Madison, WI, United States of America.

Plos One
|October 27, 2021
PubMed
Summary
This summary is machine-generated.

This study introduces sub-pixel encoding (SPE), a novel method to enhance X-ray imaging spatial resolution without physical motion. SPE achieves finer detail by modulating photon energy spectra, enabling visualization beyond detector element limits.

More Related Videos

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

Published on: May 27, 2008

13.3K
Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis
06:56

Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis

Published on: September 22, 2023

1.3K

Related Experiment Videos

Last Updated: Oct 15, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.6K
Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

Published on: May 27, 2008

13.3K
Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis
06:56

Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis

Published on: September 22, 2023

1.3K

Area of Science:

  • Medical Imaging
  • X-ray Technology
  • Image Resolution Enhancement

Background:

  • Traditional methods for improving X-ray spatial resolution involve reducing focal spot or detector element size.
  • Many super-resolution techniques necessitate physical movement of imaging system components.
  • A need exists for methods that enhance resolution without object or detector motion.

Purpose of the Study:

  • To introduce a novel method for achieving spatial resolution beyond the physical limits of detector pixels.
  • To demonstrate a technique that enhances spatial resolution without requiring physical movement of the object or detector.

Main Methods:

  • Introduced sub-pixel encoding (SPE), a method weighting photon energy spectra on a sub-pixel scale using physical filters.
  • Acquired multiple X-ray projections to synthesize information at a spatial scale determined by spectrum modulation.
  • Demonstrated SPE feasibility using simulated energy-integrating detectors for medical and industrial applications, resolving features smaller than detector pitch.

Main Results:

  • SPE successfully synthesized information at a finer spatial scale than the detector element size.
  • Simulations showed phantom features resolvable by SPE with a 2 mm detector that were not visible with a standard 2 mm detector, but were resolvable with a 1 mm detector.
  • Covariance matrix analysis characterized noise propagation and correlation, with negative diagonal terms observed in example cases.

Conclusions:

  • Introduced the concept of encoding and retrieving object information at a sub-pixel length scale.
  • SPE enables simultaneous enhancement of spatial resolution and provides dual-energy-like information on photon-matter interactions.