Normal imaging findings after ascending aorta prosthesis implantation on 18F-Fluorodeoxyglucose Positron Emission
Ali R Wahadat1,2,3, Wilco Tanis3, Ties A Mulders1
1Department of Radiology and Nuclear Medicine, Erasmus Medical Center, ND-547, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Background:
To diagnose abnormal 18F-Fluorodeoxyglucose (18F-FDG) uptake in suspected endocarditis after aortic root and/or ascending aorta prosthesis (ARAP) implantation, it is important to first establish the normal periprosthetic uptake on positron emission tomography with computed tomography (PET/CT).
Methods:
Patients with uncomplicated ARAP implantation were prospectively included and underwent 18F-FDG-PET/CT at either 12 (± 2) weeks (group 1) or 52 (± 8) weeks (group 2) after procedure. Uptake on three different locations of the prosthesis ("cranial anastomosis (CA)," "prosthetic heart valve (PHV)," "ascending aorta prosthesis (AAP)") was scored visually (none/low/intermediate/high) and quantitatively (maximum standardized uptake value (SUVmax) and target-to-background ratio (SUVratio).
Results:
In total, 20 patients (group 1: n = 10, group 2: n = 10) (mean age 64±7 years, 70% male) were included. Both groups had similar visual uptake intensity for all measured areas (CA: mostly low-intermediate (16/20 (80%)), p = .17; PHV: low-intermediate (16/20 (80%)), p = .88; AAP: low-intermediate (19/20 (95%)), p = .48). SUVmax for CA was 5.6 [4.1-6.1] and 3.8 [3.1-5.9] (median [IQR], p = .19), and around PHV 5.0 [4.1-5.7] and 6.3 [4.6-7.1] (p = .11) for groups 1 and 2, respectively. SUVratio for CA was 2.8 [2.3-3.2] and 2.0 [1.7-2.6] (median [IQR], p = .07) and around PHV 2.5 [2.4-2.8] and 2.9 [2.3-3.5] (median [IQR], p = .26) for groups 1 and 2, respectively.
Conclusion:
No significant differences were observed between PET/CT findings at 3 months and 1 year after ARAP implantation, warranting caution in interpretation of PET/CT in the first year after implantation.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies III: Computed Tomography
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)