Related Experiment Video
Updated: Oct 15, 2025

Excitonic Hamiltonians for Calculating Optical Absorption Spectra and Optoelectronic Properties of Molecular Aggregates and Solids
Published on: May 27, 2020
Assessing cathode property prediction via exchange-correlation functionals with and without long-range dispersion
Olivia Y Long1,2, Gopalakrishnan Sai Gautam3,4, Emily A Carter3,5
1Department of Physics, Princeton University, Princeton, New Jersey 08544, USA.
Abstract:
We benchmark calculated interlayer spacings, average topotactic voltages, thermodynamic stabilities, and band gaps in layered lithium transition-metal oxides (TMOs) and their de-lithiated counterparts, which are used in lithium-ion batteries as positive electrode materials, against available experimental data. Specifically, we examine the accuracy of properties calculated within density functional theory (DFT) using eight different treatments of electron exchange-correlation: the strongly constrained and appropriately normed (SCAN) and Perdew-Burke-Ernzerhof (PBE) density functionals, Hubbard-U-corrected SCAN and PBE (i.e., SCAN+U and PBE+U), and SCAN(+U) and PBE(+U) with added long-range dispersion (D) interactions (i.e., DFT(+U)+D). van der Waals interactions are included respectively via the revised Vydrov-Van Voorhis (rVV10) for SCAN(+U) and the DFT-D3 for PBE(+U). We find that SCAN-based functionals predict larger voltages due to an underestimation of stability of the MO2 systems, while also predicting smaller interlayer spacings compared to their PBE-based counterparts. Furthermore, adding dispersion corrections to PBE has a greater effect on voltage predictions and interlayer spacings than with SCAN, indicating that DFT-SCAN - despite being a ground-state theory - fortuitously captures some short and medium-range dispersion interactions better than PBE. While SCAN-based and PBE-based functionals yield qualitatively similar band gap predictions, there is no significant quantitative improvement of SCAN-based functionals over the corresponding PBE-based versions. Finally, we expect SCAN-based functionals to yield more accurate property predictions than the respective PBE-based functionals for most TMOs, given SCAN's stronger theoretical underpinning and better predictions of systematic trends in interlayer spacings, intercalation voltages, and band gaps obtained in this work.
More Related Videos
13:56Probe Type II Band Alignment in One-Dimensional Van Der Waals Heterostructures Using First-Principles Calculations
Published on: October 12, 2019
08:44Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
Published on: August 22, 2017
Related Concept Videos
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...
π Electron Effects on Chemical Shift: Overview
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
Standard Electrode Potentials
Ion-Exchange Chromatography